K3HB-VLC-ET11 User's Manual ()

Brand: OMRON
Product model: K3HB-VLC-ET11
Name: Digital Temperature Controllers
Sort: User's Manual
File language: English
File size: 2.28MB
Input type: DC voltage/current.
Supply voltage: 100 to 240 VAC.
Comparative Output Model: 2 relay contact outputs (SPST-NO).
Highly Visible LCD Display with 2-color,
(Red and Green) LEDs.
Multi-range DC voltage/current input.
Front-panel key operation for easy setting.
Average processing function suppresses flicker K3HB-VLC-ET11 User's Manual.
Scaling, front-panel forced-zero, zero-limit functions K3HB-VLC-ET11
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate).
Finger protective cover (standard equipment) guards against electric shock.
Water- and dust-proof NEMA4X (IP66 equivalent) front panel.
Recognized to U.S. and Canadian requirements under the Component,
Recognition Program of UL K3HB-VLC-ET11 User's Manual.
CE marking. Cable length: 3 m.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit K3HB-VLC-ET11 User's Manual.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped power.)
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settings.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection. Type of input: AC current input.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement annd display, identification of the panel table K3HB-VLC-ET11 Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input cann be applied to a variety of measurement and identification situations K3HB-VLC-ET11 Manual.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-B1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-B1 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-EBCD1 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-EBCD1 AC/DC24
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-FLK1BT11 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-FLK1BT11 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-ET11 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-ET11 AC/DC24
Category: external supply 100mA DC5V type. I