OMRON
Home >> Products >> OMRON >> CS1G/CS1H/CS1D/CS1W PLC >> CS1 series PLC backplane >> CS1W-BC022 Programmable Controllers

CS1W-BC022 Programmable Controllers

OMRON CS1W-BC022 Manual And Instructions
CS1W-BC022 datasheetPDF datasheet

OMRON CS1W-BC022 Product information and technical parameters:
Brand: OMRON
Name: Programmable Controllers
Model: CS1W-BC022
Product name: CS1 CPU Backplane.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted;
2 slots(Note:Expansion Racks,
cannot be connected).
Appli cable CPU Unit: CS1 CPU Unit.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control.

Unit type: CS-series Special I/O Units.
Product name: Analog Input Units.
Specifications: I/O points, 16 inputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/8,000 (Settable to 1/4,000);
Conversion speed, 250 s/point max CS1W-BC022.
(Settable to 1 ms/point).
Externa connection, MIL connector CS1W-BC022
Current consumption: 5V, 0.15A; 26V, 0.06A.
Standards: UC1, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit CS1W-BC022.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices CS1W-BC022.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in costt and space compared,
with previous systems CS1W-BC022.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-BC022.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.